Offshore Electrical Engineering Manual

  • Format
  • Bog, paperback
  • Engelsk

Beskrivelse

Offshore Electrical Engineering Manual, Second Edition, is for electrical engineers working on offshore projects who require detailed knowledge of an array of equipment and power distribution systems. The book begins with coverage of different types of insulation, hot-spot temperatures, temperature rise, ambient air temperatures, basis of machine ratings, method of measurement of temperature rise by resistance, measurement of ambient air temperature. This is followed by coverage of AC generators, automatic voltage regulators, AC switchgear transformers, and programmable electronic systems. The emphasis throughout is on practical, ready-to-apply techniques that yield immediate and cost-effective benefits. The majority of the systems covered in the book operate at a nominal voltage of 24 y dc and, although it is not necessary for each of the systems to have separate battery and battery charger systems, the grouping criteria require more detailed discussion. The book also provides information on equipment such as dual chargers and batteries for certain vital systems, switchgear tripping/closing, and engine start batteries which are dedicated to the equipment they supply. In the case of engines which drive fire pumps, duplicate charges and batteries are also required. Packed with charts, tables, and diagrams, this work is intended to be of interest to both technical readers and to general readers. It covers electrical engineering in offshore situations, with much of the information gained in the North Sea. Some topics covered are offshore power requirements, generator selection, process drivers and starting requirements, control and monitoring systems, and cabling and equipment installation

Læs hele beskrivelsen
Detaljer
Størrelse og vægt
  • Vægt1110 g
  • coffee cup img
    10 cm
    book img
    19,1 cm
    23,4 cm

    Findes i disse kategorier...

    Se andre, der handler om...

    Computer-aided design Governors Cooling Protective relays Cells Direct current Cathodic protection Commissioning Noise control Performance standards Load Installation Glands Cast iron Connectors Fuse Load sharing Fault Tree Offshore Dynamic Positioning Offshore Installation IMO FPSO Circuit breaker Drilling Reliability analysis FMECA Power management Metering Safety case Reliability Block Diagram Gearbox Hazard Renewable energy projects Mooring Overheating Flashpoint Overcurrent Abseiling Acceptance criteria Air-to-air heat exchanger Air circuit breakers Air circuit breaker Ambient air temperatures Attracted armature relays Arc chute Bearing failures Ballast control Blowout Coils Automatic voltage regulator Ballast control panel Bus ducting Cable Support Systems Cable sizing Calibration certificate Cable rack diagram Annunciator Cement pumps Busbar zone protection Cable Trays Compound wound Back feeding Ballasting system Cast resin transformers Basis of machine ratings DARPS Busbar Direct on line starting British Standards current transformer Dynamic positioning system Commissioning checks Buchholz pressure sensing Cause-and-effect matrices Dead bus relay Emergency Shutdown System design drawings CT saturation Current transformers Drying curve Duty holder Flat compounding Fire pimp Exciters Drilling Mud Frame earth system Electronic starters Gas-ignition engine Fire Pump Emergency Control Centre Control Loop Explosive mixture Harmonic orders Gas turbine generator Control and monitoring Conventional relay types Hot-spot temperatures Hull structure Independent competent person Helidecks Independent Competent Person (ICP)Offshore installation High-voltage machine Hot work Distribution Transformers Intertripping Interturn Drainage and bilge pumping IEC 60909Short circuit Dump tank Health and Safety Executive Earth bonding Earth Fault Protection Integrated Automation System Integrated intelligent MCCs Intrinsically safe cables electrical system Electrical Tests Ignition temperature Emergency control point Emergency Escape Lighting Ingress protection Insulation Resistance Escape lighting Interturn faults Intrinsically safe lightning strikes Megohmmeter test Fault Currents Low-voltage switchgear Fault Current mean time to repair Fixed installation Measurement of ambient air temperature Leg lighting Method of measurement of temperature rise by resistance Level Zero Miniature circuit breakers Mobile drilling platforms Logic simulators Galvanic Anode Systems Low-voltage switchboard Magnetising inrush Maintenance intervals Oil-filled transformers Manned installation Nacelles Generator reactance Overload devices and ATEX Ground flare PFEER Plant� Polarisation index Portable communications Overpotential tests illuminance Public Address System Phase-to-phase fault Piper Alpha disaster Inductive couplers Power Factor Resistance temperature device People onboard problems Prime Movers Reliability-centred maintenance scheduling Safety Case Regulations (SCR)Verification Scheme Probability of failure on demand Process Control System QA System Racking gear Real and reactive power Relay setting Jack-up rig Loop calculation Low-voltage machine Magnetic noise Safety Critical Elements Installation and operating manuals Jacket lighting Jacking system Navigational lighting Nickel�cadmium cells Knockout pot Normally unmanned installation Megger tests Laydown areas Life Support Equipment load flow Load sharing system Long shunt Prime Mover Open circuit test Overcurrent Protection Motor control centre Phasor diagram pontoons Overpotential voltage Radio paging system Recombination cells Rogowski coils Precommissioning reactance Safety and Environmental Critical Elements Safety Barriers Safety Case Regulations

    Velkommen til Saxo – din danske boghandel

    Hos os kan du handle som gæst, Saxo-bruger eller Saxo-medlem – du bestemmer selv. Skulle du få brug for hjælp, sidder vores kundeservice-team klar ved både telefonerne og tasterne.

    Om medlemspriser hos Saxo

    For at købe bøger til medlemspris skal du være medlem af Saxo Premium, Saxo Shopping eller Saxo Ung. De første 7 dage er gratis for nye medlemmer. Medlemskabet fornyes automatisk og kan altid opsiges. Læs mere om fordelene ved vores forskellige medlemskaber her.

    Machine Name: SAXO080