Maintenance of Process Instrumentation in Nuclear Power Plants

Bog
  • Format
  • Bog, hardback
  • Engelsk

Beskrivelse

This book is written for the instrumentation and control engineers, technicians, and managers in nuclear power plants. It focuses on process temperature and pressure sensors and the veri?cation of these sensors’ calibration and response time. It also provides examples of typical problems and solutions with temperature and pressure measurements in nuclear power plants. Contents 1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 1. 1 Reference Plant . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 1. 2 On-Line Monitoring of Process Instruments Calibration . . . . . . . . . . 3 1. 3 Dynamic Testing of Pressure Transmitters and Sensing Lines . . . . . . 3 1. 4 On-Line Detection of Venturi Fouling . . . . . . . . . . . . . . . . . . . . . . . . . . 6 1. 5 Measuring the Vibration of Reactor Internals . . . . . . . . . . . . . . . . . . . . 8 1. 6 Detecting Core Flow Anomalies . . . . . .. . . . . . . . . . . . . . . . . . . . . . . . 10 1. 7 CANDU Reactor Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 1. 8 In-Situ Response-Time Testing of Temperature Sensors . . . . . . . . . . . 12 1. 9 Testing Cables In-Situ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 1. 10 Automated Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 2 Origins of This Book . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 2. 1 Collaborative R&D . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 2. 2 Government R&D . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 2. 3 Utility R&D . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 2. 4 IAEA Guidelines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 2. 5ISA and IEC Standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 3 Maintenance of Nuclear Plant Instrumentation . . . . . . . . . . . . . . . . . . . 27 4 Nuclear Plant Temperature Instrumentation . . . . . . . . . . . . . . . . . . . . . 29 4. 1 History of RTDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 4. 2 Nuclear-Grade RTDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 4. 3 Nuclear Plant Temperature Measurement Terminology . . . . . . . . . . . 34 4. 4 Problems with Nuclear-Grade RTDs . . . . . . . . . . . . . . . . . . . . . . . . . . . 42 4. 4. 1 Dynamic Response . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43 4. 4. 2 Failure of Extension Leads . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43 4. 4. 3 Low Insulation Resistance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44 4. 4. 4 Premature Failure . . . . . . . . .. . . . . . . . . . . . . . . . . . . . . . . . . . . 44 4. 4. 5 Wrong Calibration Tables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44 X Contents 4. 4. 6 Loose or Bad Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Læs hele beskrivelsen
Detaljer
Størrelse og vægt
coffee cup img
10 cm
book img
15,5 cm
23,5 cm

Findes i disse kategorier...

Se andre, der handler om...

Velkommen til Saxo – din danske boghandel

Hos os kan du handle som gæst, Saxo-bruger eller Saxo-medlem – du bestemmer selv. Skulle du få brug for hjælp, sidder vores kundeservice-team klar ved både telefonerne og tasterne.

Om medlemspriser hos Saxo

For at købe bøger til medlemspris skal du være medlem af Saxo Premium, Saxo Shopping eller Saxo Ung. De første 7 dage er gratis for nye medlemmer. Medlemskabet fornyes automatisk og kan altid opsiges. Læs mere om fordelene ved vores forskellige medlemskaber her.

Machine Name: SAXO080